current transformer Products
-
EI Mini Electronic AC Transformer 6V 9V 12V PCB Mount
Application:power supply
-
GDZC Transformer Winding Resistance Tester
Application:gold
-
Transformer Mag Welding Machine MST200
Application:All cars model
-
Transformer Mag Welding Machine MST250
Application:Universal
-
CRD4170 Three Element AC Current RS485 Digital Current Transducer
Application:other
-
Current Sensitive Thermal Protector For Automotive Window Lift Or Motor
OEM NO:TS
Application:Chevrolet , Dongfeng
-
HYPCIT Primary Current Injection Tester
OEM NO:HYPCIT
Application:Huaying
-
Brand New ABB ES500-9647 Current Transformers 500A
OEM NO:AW-TRA-012
Application:ABB ES500-9647
-
CHINT Residual Current Circuit Breaker
Application:DadiAuto
-
G SERIES HIGH VOLTAGE GENERATOR
Application:G SERIES HIGH VOLTAGE GENERATOR VOLTAGE GENERATOR Rated Voltage: 3kV / 3.3kV / 4.16kV / 6kV / 6.3kV / 6.6kV / 7.2kV /10kV / 10.5kV/ 11kV / 12.47kV/ 13.2kV / 13.8kV Power Range: 400kW-10000kW Rated Frequency: 50Hz/60Hz Rated Speed: 1500rpm/1800rpm Power Factor: 0.8(Lagging) Ingress Protection: IP23 / IP44 / IP54 Insulation Class: F / H(optional) Configuration: Single/double bearing Excitation System: Brushless permanent magnetic generator exctitation system ( PMG) 1)Electrical Performance Technical Characteristics Stator of High Voltage Generator Class F stator is wrapped with class F epoxy mica tape and mould pressed. Class H stator coil is operated with the mature class H insulation technology and impregnated in VPI (vacuum pressure impregnating) system. Both class F and class H stator coil are processed with anti-corona treatment. Meantime , the stator coil is designed with skewed slot structure to effectively reduce harmonic wave. Enhance the mechanical strength on the end of stator winding to effectively prevent and withstand the deformation on the end of stator caused by the sudden load or short circuit. Rotor of High Voltage Generator Triple insulated structure of the rotor coil can effectively improve the rotor turn to turn and interlayer insulation , the damp-proof and anti-corrosion ability. It will enhance the mechanical strength on the end of the winding to prevent the rotor winding from deforming under high rotation speed. Accordingly , the lifespan , reliability and environment adaptability of generator is also substantially improved. The rotating rectifier is designed as bi-section structure which is convenient for maintenance and do not require any knock down on the generator. Winding 5/6 or 2/3 pitch option can decrease the content of voltage harmonic wave and is suitable for nonlinear load application. The standard configuration is temperature sensor , PT100 and space heater Power Range The power range of ENGGA high voltage generator is from 400kW to 10000kw. Voltage Range Standard voltage is from 3kV to 13.8kV. Special voltage is available according to customers’ requirement. Frequency Range 50Hz or 60Hz are available. Poles and Speed The standard rotor configuration of high voltage generator is 4 pole salient rotor , with the speed at 1500r/min or 1800r/min. And 6/8/10/12/14 poles low/medium speed high voltage synchronous generator option is available. Waveform Distortion and Telephone Interference THD 300% In,10s). 2) Mechanical Performance Cooling Structure Radial and axial ventilation design in interior side ensures the sufficient cooling. Center Height The center height is from EG450 to EG1000 and can be customized. Installation Methord The standard installation method is IMB20 , double bearing configuration (single bearing is optional) , and can be customized according to customer’s requirement. Ingress Protection The standard ingress protection is IP23. IP44 and IP54 are optional. Cooling Method The standard configuration is IC01. The IP54 air-air cooling and air-water cooling is available. Dynamic Balancing All rotors have been dynamically balanced at factory before delivery and the accuracy of dynamic balancing conforms to ISO1940. Over Speed Capacity The generator maximum over speed is 2160rpm for 2 mins. Rotation Direction The standard generator rotation direction is clockwise viewed from the drive end of generator , while counter-clockwise rotation direction is optional according to customer’s requirement. Terminal Box The interior modular design of the generator terminal box has reserved the space for future voltage transformer and current transformer mounting. The terminal box of digital voltage regulator and auxiliary terminal box are mounted on the external side of the terminal box , which is convenient for wiring , debugging and the personal safety is assured.
-
Transformer Oil Purification Plant Factory
Application:VTP
-
Best Super High Voltage Transformer Oil Purifier
Application:changan
-
2017 High Technology Used Oil Filtration Machine,Vacuum Transformer Oil Purifier
Application:Beiqi
-
Mobile Vacuum Transformer Oil Filtration Machine
Application:MTP
-
Vacuum Transformer Oil Purification Dehydration Machine
Application:Nissan
-
Step down transformer, negative booster
Application:n/a
-
Thermostat for Battery, Ballast, Transformer, Micro Motor
Application:Auto
-
Application:Auto