Description
HIH-4602-A/C Series Relative Humidity (RH) sensors combine both relative humidity and temperature sensing in a TO-5 housing with a hydrophobic sintered stainless steel filter.
The laser-trimmed, thermoset polymer capacitive sensing elements have on-chip integrated signal conditioning.
The temperature sensor is thermally connected with the RH sensor making the HIH-4602-A/C often ideal for measuring dew point and other absolute moisture terms.
The HIH-4602-A contains an integral thermistor, while the HIH-4602-C contains an integral precision RTD.
Features
| Parameter | Minimum | Typical | Maximum | Unit |
Specific Note |
| Interchangeability (first order curve) | |||||
| 0% RH to 59% RH | -5 | 5 | % RH | ||
| 60% RH to 100% RH | -8 | 8 | % RH | ||
| Accuracy (best fit straight line) | -3.5 | +3.5 | % RH | 1 | |
| Hysterisis | 3 | % RH | |||
| Repeatability | ±0.5 | % RH | |||
| Settling time | 70 | ms | |||
| Response time (1/e in slow moving air) | 50 | s | |||
| Stability (at 50% RH in one year) | ±1.2 | % RH | |||
| Voltage supply | 4 | 5.8 | Vdc | ||
| Current supply | 200 | 500 | µA | ||
| Output voltage temp. coefficient at 50% RH, 5 V | -4 | mV/ºC | |||
| Voltage output (1st order curve fit) | VOUT=(VSUPPLY)(0.0062(sensor RH) + 0.16), typical at 25 | ||||
| Temperature compensation | True RH = (sensor RH)/(1.0546-0.00216T), T in | ||||
| Operating temperature | -40[-40] | See Figure 1. | 85[185] | [ºF] | |
| Operating humidity | 0 | See Figure 1. | 100 | % RH | 2 |
| Storage temperature | -50[-58] | 125[257] | [ºF] | ||
| Storage humidity | See Figure 2. | % RH | 2 | ||