OEM No/Model: KRD01
KRD01 series is an air-cooled electric vibration test system, with advantages of wide frequency, excellent performance, high reliability, small footprint, convenient movement, and simple operation. Capability of sine, random, classic shock and composite vibration tests to meet relevant test standards.
1. High first-order resonance frequency: Optimized design of the moving coil skeleton structure, especially the weak link such as the traditional structure of the moving coil skeleton force-transmitting angle plate, which effectively improves the force-transmitting rigidity. Adopting the compound fixing with glue connection and screw connection, the rigidity of the winding is enhanced, and the first-order common vibration frequency of the moving coil is significantly increased;
2. High reliability of the moving coil winding:The new structure and new technology of the original moving coil winding strengthening ring have significantly improved the reliability of the dynamic coil winding in high thrust, high acceleration vibration, shock and high temperature environments;
3. Capable of horizontal and vertical test:The table with horizontal slide table can be used for horizontal and vertical test. The switching method of the two directions is simple and easy to flip;
4. Full-featured digital vibration controller: with sine, random, sine on random, random on random, classic shock and shock response spectrum test functions.

Technical Specifications
|
Model Parameters |
KRD 01-03 |
KRD 01-3 |
KRD 01-6 |
KRD 01-10 |
KRD 01-15 |
KRD 01-20 |
KRD 01-30 |
KRD 01-40 |
KRD 01-50 |
| Sine Force (KN) | 0.3 | 3 | 6 | 10 | 15 | 20 | 30 | 40 | 50 |
| Random Force (KN) | 0.3 | 3 | 6 | 10 | 15 | 20 | 30 | 40 | 50 |
| Frequency Range (Hz) | 5-3000 | 5-2500 | |||||||
| Max. Load (kg) | 2 | 100 | 120 | 150 | 200 | 300 | 500 | 600 | 800 |
|
Peak-Peak Displacement (mm) |
2 | 25 | 51 | ||||||
| Max. Velocity (m/s) | 0.5 | 1.25 | 2 | 1.8 | 1.5 | ||||
| Max. Acceleration (m/s2) | 300 | 600 | 750 | 1200 | 1000 | 800 | 1000 | 850 | 1000 |
|
Equivalent Load Of Moving Parts (kg) |
1 | 5 | 6.8 | 8 | 15 | 25 | 30 | 45 | 50 |
| Table Size (mm) | 90 | 165 | 220 | 265 | 400 | 320 | 500 | ||
| Output Power of PA (kVA) | 0.4 | 4 | 8 | 12 | 24 | 36 | 48 | ||
| Overall Dimension (mm) |
465×390× 570 |
610×520× 585 |
850×640× 800 |
1115×775× 980 |
1130×920× 1080 |
||||
| Weight (kg) | 100 | 600 | 900 | 1000 | 2000 | 2500 | 3000 | 3200 | 3600 |
| Power Voltageand Consumption Power |
220V 1kVA |
380V 7kVA |
380V 16kVA |
380V 20kVA |
380V 35kVA |
380V 48kVA |
380V 60kVA |
||
| Standards | MIL-STD-810F IEC68-2-27 | ||||||||
|
Table Size (mm) |
Upper Limit of Frequency (Hz) | Reference Weight (kg) |
| 350 | 2000 | 15 |
| 400 | 2000 | 20 |
| 500 | 2000 | 25 |
| 700 | 2000 | 69 |
| 800 | 2000 | 80 |
| 400×400 | 2000 | 20 |
| 500×500 | 2000 | 25 |
| 600×600 | 2000 | 68 |
| 700×700 | 2000 | 82 |
| 800×800 | 2000 | 90 |
| 900×900 | 1200 | 120 |
| 1000×1000 | 300 | 135 |
| 1200×1200 | 250 | 185 |
|
Table Size (mm) |
Frequency Range (Hz) | Weight of Moving Mass (kg) |
| 400×400 | 5-2000 | 18 |
| 500×500 | 5-2000 | 28 |
| 600×600 | 5-2000 | 30 |
| 700×700 | 5-2000 | 45 |
| 800×800 | 5-2000 | 85 |
| 900×900 | 5-1600 | 90 |
| 1000×1000 | 5-1600 | 225 |
| 1200×1200 | 5-1200 | 230 |
Related Product Tags:
turbocharger balancing machine , balancing machine , battery tester , bench , body bench , body repair bench , repair bench , testing bench , auto bench , brake tester , Clutch Tester , common rail system , common rail test stand , common rail test bench , common rail tester , diesel fuel pump , diesel test bench , four wheel aligner