CK200201 bus air condition controller
CK200201 automatic controller applies to bus internal climate control .
Main functions: Auto control, Cooling, Fresh air, Self-check, Power lost Memory, Error alarm, Auto over-voltage protection, Air direction regulate, Multilevel air-flow regulator, Shift function.
The shift function
1) Running time check (press fan button no less than 3S )(Press self-
check button for no less than 3S, display valueX100=ventilation time)
2) Defrost temp. display (press fresh air button for no less than 3S)
3) Hold cooling (press cooling button for no less than 3S)
Application
YUTONG ,ZHONGTONG
Technical data
Power supply |
24V(DC20V-DC32V) |
Power consumption | 3W |
Current | Max.200mA |
Dimensions | 168X66X54mm |
Input |
1)Interior temp. sensor(25,Rb=5K,B=3274) 2) Defrost sensor(25,Rb=5K,B=3274) 3) Pressure sensor 4) Power(generator) 5) ACC power(battery) 6) Backup lamp power |
Output |
1) Condenser fan (max. 0.3A) 2) Fan high (max. 0.3A) 3) Fan medium (max. 0.3A) 4) Fan low (max. 0.3A) 5) Fresh air on (max. 0.3A) 6) Fresh air off (max. 0.3A) 7) Compressor clutch(max. 0.3A) 8) Excitation(max. 0.3A) |
Display | LED (true color/red) |
Ambient temperature | -30805%95%RH Non-condensing |
Storage temperature | -10705%95%RH Non-condensing |
Display precision | Set temp for dual digit display, accuracy 1; Interior temp dual digit display. accuracy 1. |
Temperature test standard | Temp. control based on the temp. of return air inlet, the defrost sensor controls defrost temp., defrost on at 2, defrost off at 4 |
Connector | Plug DJ7171-3-21;terminal:DJ621-F3*0.6A tinned |
Faceplate level | IP43 |
EMC level | EN50081&EN50082-2 |
Security level | Applied to EN61010-II, Pollution degree: II |
Weight | 308g |