CK200204 dual compressor air conditioning controller(cool)
CK200204 fully-automatic climate controller applies to the climate control for dual-compressor bus.
Main functions:fully-automatic control, cool, fresh air, memory, error alarm, shift function, input voltage detecting.
The shift function
1)Defrost temp. display (press fresh air button for no less than 3S)
2))Hold cooling (press cool button for no less than 3S)
Application
YUTONG Bus, ZHONGTONG Bus,
KINGLONG Bus
Technical data
Power supply |
24V(DC20V-DC32V) |
Power consumption | 4.5W |
Current | Max.210mA |
Dimensions | 168X66X54mm |
Input |
1) Interior temp. sensor(25,Rb=5K,B=3274) 2) Defrost sensor 1,2(25,Rb=5K,B=3274) 3) Pressure sensor 1,2 4) Power(generator) 5) ACC(battery) 6) Backlight power |
Output |
1) Condenser fan(max0.3A) 2) Fan high (max0.3A) 3) Fan medium (max0.3A) 4) Fan low (max0.3A) 5) Fresh air on (max0.3A) 6) Fresh air off (max0.3A) 7) Compressor clutch 1(max0.3A) 8) Compressor clutch 2(max0.3A) |
Display | LED (true color/red) |
Ambient temperature | -30805%95%RH Non-condensing |
Storage temperature | -10705%95%RH Non-condensing |
Display precision | Dual digit display of set temp., accuracy 1; dual digit display of inside temp. accuracy 1 |
Temperature test standard | Temp. control based on the temp. of return air inlet, the defrost sensor controls defrost temp., defrost on at 2, defrost off at 7 |
Connector | Plug DJ7171-3-21 |
Faceplate level | IP43 |
EMC level | EN50081&EN50082-2 |
Security level | Applied to EN61010-II, Pollution degree: II |
Weight | 335g |