Product Attribute:
Length:28cm
Width:25cm
Height:20cm
model:INTL-XZC830
groove:6pk
voltage:12V
pulley diameter:120mm
car made:for Citroen/Fiat/Lancia/Peugeot/Renault
parts number:1209F 1209 9630014080 71789353 71723461 71723460 71789351
compressor type:Sanden 7V16
Applicationt: 
Citroen (Fiat)
Production Description:
Our factory can produce many kinds of auto Air Conditioner Compressors with good quality and one year quality warrantee.
7V16 ac compressor for Citroen/Fiat/Lancia/Peugeot/Renault
Specification:
Model Number: INTL-XZC830
Car name: for Citroen/Fiat/Lancia/Peugeot/Renault
Compressor type: for Sanden 7V16
Clutch DIA: 120mm
Grooves: PV6
Volt:12v
OEM:
Sanden:
1209F
1209
9630014080
71789353
71723461
71723460
71789351
Details
for Citroen C5 3.0 V6 2001/2005
for Citroen C8 3.0 V6 2002/2014
for Citroen Xantia 2.9i V6 1993/1998
for Citroen Xantia 3.0i V6 1998/2003
for Citroen XM 3.0 V6 1994/2000
for Peugeot 406 2.9 V6 1995/2004
for Peugeot 406 3.0 V6 1995/2004
for Peugeot 406 2.0 1995/2004
for Peugeot 406 2.9 V6 1996/2004
for Peugeot 406 3.0 V6 1996/2004
for PEUGEOT 504
for PEUGEOT 505
for PEUGEOT 605 (6B)
for Peugeot 607 2.9 V6 1999/2009
for Peugeot 807 3.0 V6 2002/2014
for Renault Espace 3.0i V6 1996/2002
for Renault Laguna I 2.9 V6 1993/2001
for Renault Laguna I 3.0 V6 1993/2001
for Renault Laguna II 3.0 V6 2001/2007
for RENAULT AVANTIME (DE0_)
for RENAULT CLIO II (BB0/1/2_, CB0/1/2_)
for FIAT ULYSSE (179AX)
for LANCIA PHEDRA (179)
Basic Requirements when servicing an A/C system:
1, The Accumulator or Filter Drier should always be replaced when the Air Conditioning System is opened. For warranty Purposes buyer must show evidence of receiver/drier replacement. In some vehicles the drier comes attached to the condenser so it must replaced as well
2. A/C system must be clean and free of debris and contaminants. In most cases components can be flushed; however in some instances it may be necessary to replace the condenser or other items.
3. Orifice tube must be replaced; expansion valve must be inspected and replaced if dirty or defective.
4. Correct amount and type of oil must be used. Please refer to the OE manufacturer for this information.
5. Prior to refrigerant charging, full vacuum must be done for a minimum of 45 minutes. In humid climates or during cooler days, this time should be increased to effectively remove air and boil off moisture.
6. The Orifice Tube, if equipped, should always be replaced and the Expansion Valve, if equipped, should at least be inspected for proper operation if not replaced