Impulse Voltage Testing System

Impulse Voltage Testing System

Application:  Acura

Market Type:  After Market

Packing:  Plywood Case

Samples:  Not Available

Maximum Prodcution Capacity:  100 Per Mointh

Delivery Time:  7 Working Days

Place of origin:  China

Export Ratio:  31% - 40%

Unit Price:  USD 100

Price Terms:  FOB

Delivery Port:  Guangzhou

Minimum Order:  1Set/Sets

Product Attribute:

Type:other

Applicationt: 

Acura

Production Description:

Product DescriptionGeneral Information:
This impulse test system is used for carrying out standard lightning impulse voltage full wave and operation wave tests on HV apparatus such as power capacitors, clearance, bushings, power transformers and CT/PT at 10kV or below.

Main Parameters for System

Nominal voltage: ±200kV

Rated stage voltage: ±100kV

Rated energy: 10kJ

Impulse capacitance: 0.5µF

Number of stages: 2

Rated stage capacitance: 1µF(each impulse capacitor 1µF at 100kV, total 2pcs)

Impulse voltage waveform: generated when load capacitance is 300-3000pF.T1=1.2µs±30%, T2=50µs±20%, standard lightning impulse voltage full waveform of  peak voltage deviation3%; 
Standard operation waveform 250±20%/2500±60%. These 2 Impulse voltage  waveform parameters and error are accorded with national requirements of GB311.1and GB16927.1 standard and IEC standard.

Voltage utilization factor: Standard lightning impulse voltage waveform 90% when load capacitance is below 1000pF, standard operation impulse voltage waveform80% when load capacitance is below 2000pF. Standard operation impulse voltage waveform 70%.

Locking range: level voltage is within the range of 20%-100% rated voltage, positive and negative locking range no less than 25%.

Out-of-control rate of synchronous discharge: <5%

Min. output voltage: ±20% of rated voltage.

Instability of discharge voltage: <±1.0%

Continuous time: Above 2/3 of rated voltage, continuous working when charge and discharge once every 120s. Below 2/3 of rated voltage, continuous working when charge and discharge once every 60s.

Above information for reference using, please contact us for further technical details.
 