Home » Showroom » » Products » Meter » Fully Automatic CT Analyzer Multi-function CT Analyzer
Company Info
Chongqing Gold M & E Co. , Ltd

Street Address: 9/ 10 Jintai Building Nanping Street Nanan District

City: Chongqing

Province: Chongqing

Country/Region: China

View Contact Details

Fully Automatic CT Analyzer Multi-function CT Analyzer

Fully Automatic CT Analyzer Multi-function CT Analyzer

Application:  Safety regulations for CT (PT ...

OEM No/Model:  GDVA-405

Market Type:  After Market

Maximum Prodcution Capacity:  1000

Place of origin:  China,Chongqing

Minimum Order:  1

Applicationt: 

Safety regulations for CT (PT testing equipment application)

Production Description:

I.Features -Safety regulations for CT/PT testing equipment application -All technical index should keep in work condition before testing with Analyzer. -Please follow associated international standards in a special application. -Forbid high voltage or high current connected to CT/PT Analyzer directly. -All tests need to follow procedure in user manual. -It is forbid to open the box of CT/PT Analyzer. Otherwise, the quality assurance will be invalid. -It is forbid to update or extend the tester without manufacturer authorization. -Please use the original accessories for Analyzer. -It is forbid to cut off test connection before LED indicator light is OFF. -Please connect Analyzer to ground with grounding cable in no laboratory application. -Please confirm that one terminal of sample CT primary connected to ground. -Do not run Analyzer in extreme moist condition. -Please confirm that all terminals connected to Analyzer have no voltage. All voltage outputs are from CT/PT Analyzer. -Please confirm that voltage had been injected to CT secondary winding in CT test. Otherwise, CT/PT Analyzer will be damaged possibly. -Please confirm that voltage had been injected to PT primary winding in PT ratio test. Otherwise, CT/PT Analyzer will be damaged possibly. -The ratio error and phase angle error test is valid for electromagnetic voltage transformer only. It can not applied in CVT test. II.CT PT Analyzer technical index Tests for Current Transformer: -Excitation curve and parameters test -Turns ratio test -Ratio and phase error test -Polarity mark check -Winding resistance measurement -Secondary loop burden measurement -Error line curve test for protection CT -Transient CT parameters test -CT nameplate guess -Saturation hysteresis loop curve measurement Tests for Voltage Transformer: -Turns ratio test -Ratio error and phase angle error test -Polarity test -Secondary burden test -Winding resistance test Applications of CT/PT Analyzer: -CT nameplate check -CT parameters check in work burden -CT transient parameters analysis -CT ratio and phase error calibration -PT routine test III---CT tester Technical index Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13 -Power supply: AC220V±10%,50Hz/60Hz±10% -Power output: 0.1~180V (AC) -Current output: 0.001~5A(RMS) -Maximum knee voltage measurement; 45kv -Current measurement: Range:0~10A (automatically change range in 0.1/0.4/2/10A) Error 0.1% 5000~35000 error 1000groups -Work condition: Temperature:-10℃~50℃, moist:≤90% -Size: 485mm×356mm×183mm -Weight: 15Kg

Send your message to this supplier

Enter between 20 to 3,000 characters, English only.
http://en.gasgoo.com/new/common/contactsupplier.aspx?type=4&id=1117782