Home » Showroom » » Products » Repair Tools » Mst-406en Automotive Emission Exhaust Gas Analyzer (4-Gas - Portable)
Company Info
Master Automobile Co. , Ltd Master Automobile Co. , Ltd

Street Address: Room 702, North Of Guoqing Road, Old Road Bureau

City: Chenzhou

Province: Hunan

Country/Region: China

View Contact Details

Mst-406en Automotive Emission Exhaust Gas Analyzer (4-Gas - Portable)

Mst-406en Automotive Emission Exhaust Gas Analyzer (4-Gas - Portable)

Application:  all type of vehicle email: ...

OEM No/Model:  Mst-406EN

Market Type:  After Market

Packing:  STANDARD PACKING

Samples:  Charge

Maximum Prodcution Capacity:  3000SET/MONTH

Delivery Time:  Within 3 Days After Payment Recieved.

Place of origin:  China

Export Ratio:  91% - 100%

Unit Price:  USD 1500

Price Terms:  FOB

Delivery Port:  Any Port Of China

Minimum Order:  1Set/Sets

Product Attribute:

Applicationt: 

all type of vehicle
email: autodiagnosis1 AT autodiagtool DOT com SKype: laural_luo MSN: laural_luo AT hotmail DOT com Cell: +86 18670295282

Production Description:

Product Description

MST-406EN Automotive Emission Analyzer(4-Gas / Portable)
Skype: laural_luo
laural:0086-18670295282


Main Features and Specifications
1. Measure concentration of HC, CO, CO2, O2 contained in exhaust gases from gasoline engine of vehicles. Advanced NDIR (non-Dispersive Infrared) analysis technology is used to measure HC, CO, CO2 and the newest generation of electrochemical technology is adopted to measure O2. Designed with LCD screen for easier setting and operation.
2. Automatic calculation and display of A/F (air-fuel-ratio)
And Lambda air ratio .
3. Emissions from vehicle engine fuels of CNG, LPG and Ethanol gasoline can be measured.
4. Small Size, light weight and most convenient for carry.
5. Designed with inductive clip-on pickup sensor for RPM
Measurement.
6. Designed with oil temperature measurement probe.
6. Designed with RS-232C digital serial interface.
7.200 groups of measurement data storage and review.
8. In compliance with accuracy requirement of ISO 3930
Or OIML R99 Class I.

Options and Accessories:
1. Micro printer.
2. Various RPM measurement adaptors.
3. DC12V vehicle power inverter.

Main Technical Specifications
Measuring Range:
HC: 0~9, 999 ppm (n-Hexane)
CO: 0~10 %
CO2: 0~18 % 2
O2: 0~25 % 2

Measurement Accuracy:
HC: ± 12 ppm (ABS. ) 0~2, 000 ppm
± 5 % ( rel. ) 0~2, 000 ppm (which ever is larger)
± 10 % ( rel. ) 2, 001~9, 999 ppm
CO: ± 0.06 % (ABS. )
± 5 % ( rel. ) (which ever is larger)
CO2: ± 0.5 % (ABS. )
± 5 % ( rel. ) (which ever is larger)
O2: ± 0.1 % (ABS. )

± 5 % ( rel. ) (which ever is larger)
Response Time: Less than 10s for T90
(O2, less than 12s)
Warm-up Time: 10 min.
(ambient temperature is not lower than 20C)
Power Supply: AC220V ± 10% 50Hz ± 1Hz
Net Weight: 6.0Kg
Outer Dimension:
260mm(W) × 180mm(H) × 450mm(D).

Send your message to this supplier

Enter between 20 to 3,000 characters, English only.
http://en.gasgoo.com/new/common/contactsupplier.aspx?type=4&id=1087893