Street Address: Hengli Town
City: Dongguan
Province: Guangdong
Country/Region: China
Bmw
air warmer thermostat Engineering structure figure: Electric kettle thermostat Technical parameters: 1.Electrical parameters:1)CQC,VDE,UL,CUL AC250V 50~60Hz 5A/10A/15A(Resistance load) 2)UL AC125V 50Hz 15A (Resistance load 2.Action temperature range: 45~160(Optional); temperature accuracy: ±2 ±3 ±5 ±10 3.Recovery and action temperature difference: 8~100(Optional) 4.Connection method: Insert the terminal 250# (bending angle: 0~90° optional); Insert the terminal 187# (bending angle: 0~90° optional; thickness: 0.5, 0.8mm optional) 5.Lifespan: 100,000 times 6.Electrical strength:No spark or breakdown for 1min at AC 50Hz 1800V 7.Contact resistance: 50m 8.Insulation resistance: 100M 9.Junction method: Constant-closed: the contact point disconnects when temperature rises; and contact point connects when temperature falls; Constant-opened: the contact point connects when temperature rises; and contact point disconnects when temperature falls. 10.Casing protective class: IP00 11.Grounding method: Connection is made between the metal casing of the temperature controller and the metal part of the grounding device. 12.Installation method: installed for KI031 series: general moving ring, mini round moving ring, flat moving ring general aluminum cover with mounting hole, extra length aluminum cover with mounting hole Electric kettle thermostat structure form naming Temperature specification naming: