DESCRIPTION
    The CRIR M1 Commercial Carbon Dioxide (CO2) sensor is a single channel, non-dispersive infrared (NDIR) sensor. Within the CRIR M1 is a sensing chamber with an infrared source at one end and a detector fitted with an optical filter at the other end. The source emits radiation at wavelengths which include the absorption band of CO2. The filter blocks wavelengths which are not sensitive to the presence of CO2, thereby increasing selectivity and sensitivity. As the light passes through the sensing chamber, a fraction is absorbed if CO2 is present. The difference between the light emitted by the source and received by the detector can then be converted to a CO2 concentration reading.
    The Automatic Baseline Correction (ABC) function can automatically calibrate the sensors lowest reading over a pre-configured interval to 400 ppm CO2. This enhances long term stability and may eliminate the need for calibration.
 
FEATURES
 Single channel, non-dispersive infrared technology
 Automatic Baseline Correction
 Temperature compensation
 UART digital interface
 
VALUE TO CUSTOMERS
 Small size
 Maintenance free for normal indoor applications
 Enhanced long term stability
 Higher accuracy: ±40 ppm ±3% of reading
 Consistency and repeatability
 Easy integration
 
POTENTIAL APPLICATIONS
 HVAC, demand controlled ventilation
 Indoor air quality (IAQ) measurement
 Air purification systems
 Smart /IoT (Internet of Things) systems
 
SPECIFICATIONS


CHARACTERISTIC
PARAMETER
Target gas carbon dioxide (CO2)
Operating principle non-dispersive infrared (NDIR)
Standard range1, 2 400 ppm to 2000 ppm, up to 10000 ppm extended range
Measurement interval 4 s
Accuracy 3 ±40 ppm ±3% of reading
Typical response time (T90) 120 s
Sensor warm-up time 3 min typical
Repeatability >97%
Operating voltage 4.5 V to 5.5 V unprotected against surges and reverse connection
Power consumption 300 mA peak, 30 mA average
Alarm output, open collector 1000 ppm/800 ppm normal state is conducting max 100 mA.
Transistor open at CO2 high or at sensor failure (see Figure 1)
Serial communication5 UART, Modbus protocol
Operating temperature range 0 to 50
Storage temperature range -40 to 70
Operating humidity 0 %RH to 90 %RH non-condensed
Expected operating life 10 years
Maintenance6 maintenance-free for normal indoor applications
Weight <8g
Dimensions 33 mm x 22 mm X 11,2 mm (tolerance ±0,5 mm)
The CRIR M1 is designed to measure CO2 in the range of 400 ppm to 2000 ppm with the accuracy specified in Table 1; however, exposure to concentrations below 400 ppm may result in incorrect operation of the ABC algorithm and should be avoided when the ABC is ON.
The CO2 sensor provides readings via UART in the extended range; however, the accuracy is reduced.
In normal IAQ applications, the sensor accuracy is defined after a minimum of three ABC periods of continuous operation.
The sensor accuracy is specified over the operating temperature range and referenced to certified calibration mixtures. Uncertainty of calibration gas mixtures (±1% currently) is to be added to the specified accuracy for absolute measurements.
See the CRIR M1 User Guide for Modbus address and parameter definitions.
The CO2 sensor normally does not require maintenance in IAQ applications; however, for some industrial applications, maintenance may be required.

Send your message to this supplier

Enter between 20 to 3,000 characters, English only.
http://en.gasgoo.com/new/common/contactsupplier.aspx?type=4&id=1120918