Optical Dissolved Oxygen Probe

Optical Dissolved Oxygen Probe

Application:  -

Market Type:  After Market

Product Attribute:

Applicationt: 

-

Production Description:

RDO® PRO-X Optical Dissolved Oxygen Probe Description:
    The RDO PRO-X Dissolved Oxygen Probe uses optical technology (EPA-approved RDO technology for Clean Water Act programs) to measure dissolved oxygen and temperature in demanding process environments. This durable probe requires no calibration or conditioning prior to deployment and does not use membranes. The replaceable RDO Smart Sensor Cap stores calibration coefficients for automatic, error-free setup.
    Use flexible communication protocols (4-20 mA, Modbus/RS485, or SDI-12) and easily integrate with PLC systems, telemetry systems and/or HydroVu Data services for real-time feedback within your system.
    With the RDO PRO-X, NPDES permit holders can monitor influent, effluent and treatment processes and respond quickly to oxygen and temperature changes for more accurate and efficient process control.
 
RDO® PRO-X Optical Dissolved Oxygen Probe Applications:

  •  MUNICIPAL/INDUSTRIAL WATER AND WASTEWATER TREATMENT
  •  FOOD/BEVERAGE PROCESS CONTROL
  •  AQUACULTURE SETTINGS
  •  DAM DISCHARGE MONITORING
 
RDO® PRO-X Optical Dissolved Oxygen Probe Technical parameters:
RDO PRO-X OXYGEN PROBE
SENSOR TYPE Optical DO probe uses Classic Sensor Cap.
RANGE, DO 0-60 mg/L
ACCURACY, DO ±0.1 mg/L, 0 to 20 mg/L
±2% of reading, 20 to 60 mg/L
RESOLUTION, DO 0.01 mg/L
RESPONSE TIME, CAP T90: <45 sec. T95: <60 sec. @ 25
RANGE, TEMP. 0°to 50 (32°to 122°F)
ACCURACY, TEMP. ±0.1 typical
RESOLUTION, TEMP. 0.01
UNITS, TEMP. Celsius, Fahrenheit
SALINITY COMP. Fixed or real-time capable
BAROMETRIC COMP. Fixed or real-time capable
METHODS EPA-approved In-Situ® RDO methods 1002-8-2009,
1003-8-2009, 1004-8-2009 Standard Methods 4500-O
ENVIRONMENTAL RATINGS
PRESSURE 150 psi from 0° to 50; 300 psi @ 25
DEPTH 210m (689ft) @ 25
OPERATING TEMP. Probe: 0°to 50 (32°to 122°F)
STORAGE TEMP. Sensor cap: 1°to 60 (33°to 140°F), in factory container
Probe: -5°to 60 (23°to 140°F)
COMPLIANCE Heavy industrial, IEC 61000-6-2:2005
IP RATING IP-67 with sensor cap off; IP-68 with sensor cap installed
CHEMICAL RATINGS
INTERFERENCES Alcohols >5%; hydrogen peroxide > 3%; sodium hypochlorite (commercial bleach) > 3%; gaseous sulfur dioxide; gaseous chlorine. Do not use in organic solvents (e.g., acetone, chloroform, methylene chloride, etc.), which may swell the sensing element (foil matrix) and destroy it.
GENERAL RATINGS
COMMUNICATION OUTPUT Modbus/RS485, SDI-12, 4-20 mA
POWER REQUIREMENTS 8 to 36 VDC
POWER CONSUMPTION Maximum: 50 mA at 12 VDC
CABLE LENGTHS Modbus and 4-20 mA: Up to 1,219 m (4,000 ft)SDI-12: Up to 61 m (200 ft)
INT. MOUNTING THREAD 1-1/4 NPT
WARRANTY Probe: 3 years from date of shipment
Cap: 2 years in typical applications

Specifications are subject to change without notice.