Product Attribute:
Applicationt: 
-
Production Description:
Product Summary
Industrial grade resistance type humidity sensor: SYH-2R offers cost effective and convenient humidity measurement.
While maintaining the attractive features such as no-calibration requirement and high interchangeability of resistive type humidity sensor: SYH-1, SYH-2R widens the scope of applications to home appliances, HVAC, and automotive.
Coated with patented polymer, SYH-2R can be used in demanding environments (-20°C~85°C) with frequent condensing and chemical vapors.
SYH-2R can be directly connected to µ-com with ADC or RFC converting resistance changes to either voltage or frequency. It can also be modularized to voltage output with oscillator.
Features
-
Wide range of applications
-
Excellent Reliability
-
Water proof
-
RoHS Compliant
-
Interchangeability
Application
-
Energy Saving HVAC Control
-
Air Conditioning, Refrigeration, IAQ monitoring, Vent Fans, Home Appliances, Humi /Dehumidifiers
-
Process Control & Instrumentations
-
Medical Instruments, Handheld Devices, Weather Stations, Food Processing, Printers, RFID
Dimensions
Sensor Performance
Electrical Characteristics
|
Min |
Spec |
Max |
Rated voltage (VRMS) |
|
1 |
5 |
Rated power (mW) |
|
0.26 |
|
Standard characteristics () |
|
33 |
|
Operating temperature () |
-20 |
|
85 |
Operating humidity (%RH) |
10 |
|
95 |
Operating Frequency (kHz) |
0.1 |
|
10 |
Storage temperature () |
-20 |
|
85 |
Storage humidity (%RH) |
|
|
95 |
Accuracy (%RH) 1 |
-3 |
|
3 |
Hysteresis (%RH) |
-2 |
|
2 |
Response time (T80, sec.) 2 |
|
|
45 |
Temperature coefficient(%RH/) |
|
-0.5 |
|
1. Accuracies measured at 25, 60%RH, 1.0VRMS, 1kHz
2. Measured at 25, 1m/sec airflow for achieving 80% of step from 30%RH to 90%RH
Reliability
Test |
Condition |
HTS |
85, 1,000 hrs |
LTS |
-20, 1,000 hrs |
THB |
85, 85%RH,1,000 hrs, Bias |
HC |
3090%RH, 25, 100 times |
TC |
-2085, 100 times |
Organic solvent |
Benzene, Xylene, Toluene, 300hrs |
M/C(drop) |
100 drop, 3 times |
Vibration |
X-Y-Z, 10~55Hz, 2hrs |
Soldering heat |
260±5, 3 sec. |
Tensile |
500g(4.9N), 10 sec. |
Pass Criteria
1. The Resistance Characteristics change from the initial value of each test sample should be less than ±5%RH at 25, 60%RH
2. No extraordinary changes of the sensor i.e. Electrode migration, polymer evaporation, color, breakdown, crack etc.