Home » Showroom » » Products » Other parts » Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
Company Info
Shenzhen Isweek Ltd Shenzhen Isweek Ltd

Street Address: 16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan

City: Shenzhen

Province: Guangdong

Country/Region: China

View Contact Details

Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor

Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor

Application:  -

Market Type:  After Market

Product Attribute:

Applicationt: 

-

Production Description:

1.OKS-1 Electrochemical Oxygen Sensor Descriprion:

  •  Measures Oxygen From 0 to 100%
  •  Electrochemical Fuel Cell Sensor Technology
  •  Self Containted, No Need To Add Electrolyte
  •  Excellent Stability, Performance & Linearity
  •  Competitive Field Replacement
 
2.OKS-1 Electrochemical Oxygen Sensor Specifications:
Sensor Technology Electrochemical
Signal Output1 9 - 13 mV
Measuring Range 0 - 100 Percent
Response Time T90 13 Seconds
Accuracy Full Scale2 ± 1% of Signal
Repeatability F.S. ± 0.5%
Temperature Compensated
Operating Temp 0 to 45 
Storage Temp 0 to 45
Cross Sensitivity Meets EN12598
Recommended Flow 0.4 - 20 SCFH
Housing Material White ABS
Humidity 0 - 100% RH(Non - Condensing)
Expected Life3 < 60 Months
Storage 12 Months
Warranty4 12 Months
1. Signal Output is measured in air at 25 º C, Sea Level.
2. Full Scale Accuacy is calculated with constant pressure, temperature and proper calibration (80% O2 Value on
Full Scale Range). Drastic Temperature change can result in a maximum error of ± 10%.
3. Expected life is calculated when O2 < 20.9% @ 25 º C, Sea Level.
4. Oksidyne Healthcare Ltd. Warrants the sensors for the period noted above to be free from defects in materials
and workmanship. Oksidyne will not be held liable for sensors damaged due to customer neglect.
4. Oksidyne Healthcare Ltd. sensors are tested and validated to BSI Standard BS EN 50104:2010

 
3.OKS-1 Electrochemical Oxygen Sensor Electrical & Gas Connection:
  •  M16 x 1.0mm Thread w/ Oring
  •  3-Pin Molex Header (MOLEX 22-29-2031)
 
4.OKS-1 Electrochemical Oxygen Sensor Electrical & Gas Intended Use:
    These oxygen sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia, critical care, incubators and general oxygen monitors.

Send your message to this supplier

Enter between 20 to 3,000 characters, English only.
http://en.gasgoo.com/new/common/contactsupplier.aspx?type=4&id=1120918