Home » Showroom » » Products » Other parts » FSM-10H-01 Pre-Calibrated Combustible Gas Sensor Module
Company Info
Shenzhen Isweek Ltd Shenzhen Isweek Ltd

Street Address: 16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan

City: Shenzhen

Province: Guangdong

Country/Region: China

View Contact Details

FSM-10H-01 Pre-Calibrated Combustible Gas Sensor Module

FSM-10H-01 Pre-Calibrated Combustible Gas Sensor Module

Application:  other

Market Type:  After Market

Maximum Prodcution Capacity:  3000 Pcs/Month

Delivery Time:  5~7 Work Days

Place of origin:  Japan

Price Terms:  FOB

Delivery Port:  HK

Minimum Order:  1Piece/Pieces

Product Attribute:

Applicationt: 

other

Production Description:

FSM-10H-01 Pre-calibrated Module for LPG Gas
FSM-10H-01 is Pre-calibrated Module for LPG gas alarm which applies TGS2610-D00 sensor together, it features durability and stability. The module  outputs  PWM  signal which  is proportional to LPG gas concentration (The module has a memory which is stored with factory calibration data), also is capable of detecting sensor wire breakage and short. The module can operate at wide temperature from -10~70°C.

Furthermore, the unit is less sensitivity to VOCs gas, it immunes poison by silicon compounds, it suits to work at rugged environment.

FSM-10H-01 Combustible Gas Sensor Module Features
PWM, USART digital output proportional to gas concentration
Maintain Free
Compact size, low cost
Meets RoHS requirement

FSM-10H-01 Combustible Gas Sensor Module Applications
Detect flammable gas leakage
Flammable gas leakage Detector
Industrial detector

FSM-10H-01 Combustible Gas Sensor Module Specification

Product name Combustible gas sensor module
Model No. FSM-10H-01
Gas sensor TGS2610-D00(Semiconductor)
Detection range 0 ~ 4,000ppm H2
(also can detect methane, iso-butane, and propane)
Error ± 300ppm
Output voltage
(Vconc)
PWM(2KHz)
Trouble Trouble:H, Normal:L
Response time (T90) 30S
Operating conditions -10°C ~+70°C, 20~95%RH(No condensing)
Storage conditions -10°C ~+80°C, 20~95%RH
Input voltage (VIN) 5.0±0.2V DC
Power consumption 1.5W
Weight 15g or less
Dimensions 26*27mm
Standard test conditions Ambient conditions 20±2°C, 65±5%RH
Circuit conditions 5.0±0.2V
Conditioning period
prior to test
10 minutes