Home » Showroom » » Products » Other parts » High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100% - SprintIR
Company Info
Shenzhen Isweek Ltd Shenzhen Isweek Ltd

Street Address: 16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan

City: Shenzhen

Province: Guangdong

Country/Region: China

View Contact Details

High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100% - SprintIR

High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100% - SprintIR

Application:  other

Market Type:  After Market

Maximum Prodcution Capacity:  3000 Pcs/Month

Delivery Time:  5~7 Work Days

Place of origin:  United Kingdom

Price Terms:  FOB

Delivery Port:  HK

Payment Terms:  T/T

Minimum Order:  1PCS

Product Attribute:

Applicationt: 

other

Production Description:

SprintIR

High Speed NDIR Carbon Dioxide Sensor

Summary
SprintIR is a high speed (20 Hz) CO2 sensor, ideally suited for applications which require capture of rapidly changing CO2 concentrations including metabolic assessment and analytical instrumentation.

Fast, Accurate Carbon Dioxide Sensor
The SprintIR carbon dioxide sensor is the fastest, most accurate CO2 sensor on the market. A breakthrough in NDIR technology, the SprintIR uses advanced solid state Indium Antimonide LEDs and detectors to offer a robust sensor with no moving parts, no heated filaments, and incredibly low power requirements. The sensor comes in four versions - from 0% to 100% - all capable of the same high-speed CO2 measurement. This makes the SprintIR especially useful in biological applications.

    High speed sensing (20Hz)
    Measurement ranges from 0 to 100%
    3.3V supply
    Low power requirement 35mW
    Flow through adaptor (Optional)

 

Specifications

CO2 Measurement

Sensing Method

Non-dispersive infrared (NDIR) absorption

Patented Gold-plated optics

Patented Solid-state source and detector

Sample Method

Diffusion(Standard) / Flow through (with flow-through adapter)

Measurement Range

0-5%, 0-20%, 0-60%, 0-100%

Accuracy

±70 ppm +/- 5% of reading

Measurement Noise

<10% of reading with no digital filtering

Non Linearity

< 1% of FS

Pressure Dependence

0.1% of reading per mbar in normal atmospheric conditions

Operating Pressure Range

950 mbar to 10 bar

General Performance

Warm-up Time

< 1 minute

Operating Conditions

0°C to 50°C (Standard)

-25°C to 55°C (Extended range)

0 to 95%, RH non-condensing

Recommended Storage

-30°C to +70°C

Electrical/ Mechanical

Power Input

3.2 to 5V. (3.3V recommended)

Peak current 100mA

Average Current <15mA

Power Consumption

35 mW

Output

UART only 

 

Send your message to this supplier

Enter between 20 to 3,000 characters, English only.
http://en.gasgoo.com/new/common/contactsupplier.aspx?type=4&id=1120918