1,Diesel Generator Set  Data

Set Type

XG 64GF - XG 600GF

Rated Output

64 – 600(KW)

Rated Capacity

80 - 750(KVA)

Rated Current

115.2 - 1080(A)

Rated Frequency

50(Hz)

Start-up time

5~6(s)

Power Factor

0.8(Lag)

Rated Voltage

400/230(V)

2,Diesel Engine Data

Diesel Engine Model

D1146/ D1146T/

P086TI-1/ P086TI /

P126TI / P126TI-II/

P158LE-1/ P158LE/ P158LE-S /

P180LE-S /

P222LE / P222LE-S/ P222LE-II

Manufacturer

Daewoo

Rated Speed

1500(r/min)

Fuel Consumption

7 - 162(L/h)

Start battery voltage

24V DC starter

Cooling Way

Water-cooled

Induction system

Turbocharged and Intercooled

Total lubrication system capacity

18 - 98L

Total coolant capacity Dimensions

16 - 90L

Cycle

4 stroke

Number of cylinders

4 - 12

Speed  mode

Electronic governor

3,Alternator Data

Manufacturer

Shanghai Kepu Electric Co., Ltd

Dynamo Model

TFW2-100-4 to TFW2-600-4

Excitation Mode

Brushless and self-encouragement

Efficiency

95%

Protection Level

IP22/23

Number of phase and Access Act

Three-phase four-wire

Insulation Class

H

Overload

(PRP)110% load can run 1h

Automatic voltage regulator (AVR)

D203,Buffering function with a sudden load increase

Forms

Brushless and self-encouragement,Self-cooling,Measures to suppress the radio interference

4,Genset Electrical Performance

Voltage regulation(%)

≤±1(Stable )   +20~-15(Transient)

Frequency regulation(%)

≤1(Stable)    +10~-7(Transient)

Voltage fluctuation rate(%)

≤0.5

Frequency fluctuations rate (%)

≤0.5

Mutation load voltage stabilization time(S)

≤1

Load mutation frequency settling time(S)

≤1

Waveform Distortion(%)

≤5