Rotary
1.condition protect,no dirty and no contaminative 2 wet dail 3magnetic drive 4reading clearly
1.Application
usually using for measuring the total quantity of cold potable water passing through the pipeline ,for the household and residential usage .
2.specification
a)can reach the standard:ISO4064
b)work conditions
(1)water temperature :≤40°c
(2)nomiinal pressure:≤1.0Mpa
(3)pressure loss:≤0.1Mpa
(4)error indication
the lower zone from incluing the minmum flow to excluding the transitional flow :±5%
the upper zone from including the transitional flow to including the maximum flow:±-2%
c)technical date
Nominal diameter
Measuring Class
Qmax
Qn
Qt
Qmin
Qs
Wet-dial
Dry-dial
M3/H
15mm
A
3
1.5
1.150
0.045
≤0.014
≤0.016
B
0.120
0.030
≤0.010
≤0.012
20mm
5
2.5
0.250
0.075
≤0.019
≤0.020
0.200
0.050
Drawing of the structure and outer shape and installation size
Diameter
Lenght
lLenght
Width
Height
Continuous thread
Weight
mm
d
D
kg
15
253
165
99
109
ZG1/2
ZG3/4
1.6
20
290
195
111
ZG1
2.1