Home » Showroom » » Products » Manufacturing Equipment » Generator Controllers DSE7320 MKII
Company Info
Guangxi Dingbo Electricity Equipment Co. , Ltd Guangxi Dingbo Electricity Equipment Co. , Ltd

Street Address: No. 10 Kechuang Road, High and New Tech Development Zone

City: Nanning

Province: Guangxi

Country/Region: China

View Contact Details

Generator Controllers DSE7320 MKII

Generator Controllers DSE7320 MKII

Application:  Generator Controllers DSE7320 ...

Market Type:  After Market

Packing:  Wooden Case

Samples:  Free

Maximum Prodcution Capacity:  700 Sets/Month

Delivery Time:  20 Days After Payment

Place of origin:  China

Delivery Port:  Any Port In China

Minimum Order:  1Set/Sets

Product Attribute:

Applicationt: 

Generator Controllers DSE7320 MKII AUTO MAINS FAILURE CONTROL MODULE The DSE7320 MKII is a powerful, new generation Auto Mains Failure genset control module with a highly sophisticated level of new features and functions, presented in the usual DSE user-friendly format. Suitable for a wide variety of single, diesel or gas Gen-set applications. Featuring a new Dual Core main processor and extended memory, the module provides faster and more powerful processing power, returning faster operational responses on intensive applications and increased functionality, with data logging facility. Monitoring an extensive number of engine parameters, the module will display warnings, shutdown and engine status information on the back-lit LCD screen, illuminated LED's, remote PC's and via SMS text alerts (with external communication device). OVERALL SIZE:245 mm x 184 mm x 51 mm (9.6" x 7.2" x 2.0") PANEL CUTOUT SIZE:220 mm x 160 mm (8.7" x 6.3") MAXIMUM PANEL THICKNESS:8.0 mm (0.3") PRODUCT VARIANTS 7320-03 - 7320 MKII Auto Mains Failure Control Module SPECIFICATION DC SUPPLY CONTINUOUS VOLTAGE RATING 8 V to 35 V Continuous 5 V for up to 1 minute CRANKING DROPOUTS Able to survive 0 V for 100 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking. MAXIMUM OPERATING CURRENT 510 mA at 12 V, 240 mA at 24 V MAXIMUM STANDBY CURRENT 330 mA at 12 V, 160 mA at 24 V CHARGE FAIL (EXCITATION RANGE 0 V to 35 V GENERATOR & MAINS (UTILITY) VOLTAGE RANGE 15 V to 415 V AC (Ph to N) 25 V to 719 V AC (Ph to Ph) FREQUENCY RANGE 3.5 Hz to 75 Hz MAGNETIC PICK UP VOLTAGE RANGE +)

Production Description:

 

 

 

 

 

 

 

     

 

      Generator Controllers DSE7320 MKII AUTO MAINS FAILURE CONTROL MODULE
The DSE7320 MKII is a powerful, new generation Auto Mains Failure genset control module with a highly sophisticated level of new features and functions, presented in the usual DSE user-friendly format. Suitable for a wide variety of single, diesel or gas Gen-set applications.
 
Featuring a new Dual Core main processor and extended memory, the module provides faster and more powerful processing power, returning faster operational responses on intensive applications and increased functionality, with data logging facility.
 
Monitoring an extensive number of engine parameters, the module will display warnings, shutdown and engine status information on the back-lit LCD screen, illuminated LED's, remote PC's and via SMS text alerts (with external communication device).
OVERALL SIZE:245 mm x 184 mm x 51 mm (9.6" x 7.2" x 2.0")
PANEL CUTOUT SIZE:220 mm x 160 mm (8.7" x 6.3")
MAXIMUM PANEL THICKNESS:8.0 mm (0.3")
PRODUCT VARIANTS
7320-03 - 7320 MKII Auto Mains Failure Control Module
 
SPECIFICATION
DC SUPPLY
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
5 V for up to 1 minute
CRANKING DROPOUTS
Able to survive 0 V for 100 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking.
MAXIMUM OPERATING CURRENT
510 mA at 12 V, 240 mA at 24 V
MAXIMUM STANDBY CURRENT
330 mA at 12 V, 160 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
GENERATOR & MAINS (UTILITY)
VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
25 V to 719 V AC (Ph to Ph)
FREQUENCY RANGE
3.5 Hz to 75 Hz
MAGNETIC PICK UP
VOLTAGE RANGE
+/- 0.5 V to 70 V
FREQUENCY RANGE
10,000 Hz (max)
 
KEY FEATURES
Comprehensive monitoring of the mains (utility) supply and auto changeover.
4-line back-lit LCD text display
Five key menu navigation
Support for up to three remote display units
Configurable inputs (8)
Configurable analogue / digital inputs (6)
Configurable outputs (8)
Tier 4 CAN engine support.
Integral PLC editor.
Manual fuel pump control.
Power monitoring (kW h, kVAr, kv Ah, kV Ar h), reverse power protection, kW overload protection.
Mains monitoring and automatic start and changeover to generator power in the event of a mains (utility) out of limits or failure.
Configurable CT positioning.
Data logging facility
Customisable power up text and images
Support for 0-10 V & 4-20mA oil pressure senders.

Send your message to this supplier

Enter between 20 to 3,000 characters, English only.
http://en.gasgoo.com/new/common/contactsupplier.aspx?type=4&id=1125647