Skye have been designing and manufacturing quality, fully calibrated light sensors since 1983. As well as this UV Index sensor, the range also includes UVA and UVB sensors (see seperate datasheets).
This UVI Index sensor has a response closely matching the Erythema Action Spectrum, the damaging portion of the solar radiation spectrum associated with sunburn and skin cancer.
The UV Index sensor gives a voltage output which can be easily scaled to UVI values with an appropriate meter e.g. Apollo Display Meter (SKA 400) i.e. ranging from 0, low risk of sunburn to 11+, dangerous levels of UV).
The sensor is calibrated against a reference traceable to National Standards under full sunlight conditions, and so is ideal for long term datalogging on meteorological stations.
SKU 440 SPECIFICATIONS
Construction | Anodised black aluminium, sealed to IP67 |
Cable |
Screened. 7-1-4-C military specification. Cable gland on sensor housing |
Sensor | Cosine corrected head. Specially formulated diffuser |
Detector | Filtered SiC Photodetector |
Spectral Response | Close to Erythemal Action Spectrum |
Output Scaling | Nominal- 0-2V = 0 - 20UVI ( 0-0.5 W m-2) |
Thermal Drift of Output | 0.075mV/ max (-20 to +50) |
Absolute calibration error (1) | typ. <3%, (5% max) |
Cosine error (2) | 3% |
Azimuth error (3) | < 1% |
Longterm stability (4) | ±2% |
Response time (5) | better than 50ms |
Mounting | M6 x 7mm tapped hole in base. Sensor supplied with. M6 x 16mm screw + 4x 1.5mm washers to suit panel thickness of 3-10mm |
Weight | 200g with 3m cable |
Temperature range | -20 to +70 |
Humidity range | 0-100% RH |
Related Product Tags:
coolant sensor , crank sensor , Crank Shaft Sensor , egr sensor , electronic sensor , s3 fuel sensor , Fuel Sender , fuel sensor , fuel sensor assembly , hall sensor , head lamp sensor , car head lamp sensor , impact sensor , mark sensor , oil level sensor , throttle sensor