Inline NDIR CH4 Sensor GENERAL CHARACTERISTICS
Measurment range 0-4.4 Vol.-% (100%UEG)
Temperature and pressure compensated
Integrated temperature measurement
RS485 interface
4-20mA interface
Inline NDIR CH4 Sensor SPECIFICATION
| Measuring gas | CH4 |
| Measurement range | 0 ... 4.4 Vol.-% (0 ... 100%UEG) |
| Resolution | ± 300ppm |
| Accuracy | < 2% of the measured value |
| Response time | < 10s |
| Heat up time | < 10min |
| Storage temperature | -20 ... +85°C |
| Operating temperature | -20 ... +65°C |
|
Operating humidity range sensor Operating humidity range electronics |
0 ... 99% (not condensated) 0 ... 85% (not condensated) |
| Interface | RS485 |
| Analogue output | 4 ... 20mA |
| Supply voltage | 10 ... 36VDC |
| Power consumption | < 2W |
| Long-term stability | < 5% of the measured value per 1 year |