OEM No/Model: Rosemount 2088 Pressure Transmitter
Measurement Types
Differential, Gauge, Absolute, Level and Flow
Output
4-20mA HART®, FOUNDATION fieldbus, PROFIBUS PA, 1-5Vdc HART® Low Power Wireless, WirelessHART
Safety Certified
SIL 2/3 certified to IEC 61508
Reference Accuracy
± 0.065% of span
± 0.05% of span (with high accuracy option P8)
Long Term Stability
0.1% of URL for 2 years
± 0.125% of URL for 5 years (with high accuracy option P8)
Rangedown
100:1
Rosemount 2088 Pressure Transmitter
Available protocols include 4-20 mA HART and 1-5 Vdc
HART Low Power
Scaled Variable enables application specific engineering
units
Choice of Stainless Steel or Alloy C-276 wetted materials
Lightweight, compact design for easy installation
Internal and external button options are available to simplify
commissioning and maintenance
The Rosemount 2090F utilizes Rosemount solid-state, polysilicon sensor for industry-leading reliability and accuracy.
The 2090F design conforms to 3-A Sanitary Standards and is accepted by the USDA. The materials of construction are Generally Recognized As Safe (GRAS) by the FDA, making it the ideal choice for food and beverage and pharmaceutical applications.
Reference Accuracy: ± 0.20% of span
Rangeability: 20:1
Installed Stability of ± 0.10% of URL for 12 months
Available in 4-20mA HART® protocol
Available in 1½- or 2-in. Tri-Clamp® connection
The 2090P can be calibrated to ranges as low as 0 to 1.5 psi (0.1 bar) and as high as 0 to 300 psi (20.7 bar). The combination of these superior measurement capabilities, its compact size and rugged construction make it ideal for pulp and paper applications.
Reference Accuracy: ± 0.20% of span
Rangeability: 20:1
Installed Stability of ± 0.10% of URL for 12 months
Available in 4-20mA HART® protocol
Available in 1-inch flush mount compatible with a PMC® process connection, or 1½-in. threaded mounting connection
Enhanced Rosemount 3051 Pressure Transmitter 3051S Advanced Diagnostics
Product
Rosemount 3051S Electronic Remote Sensors
Measurement Principle
Differential Pressure is calculated using two gage / absolute pressure sensors
Transmitter Models 3051SAM, 3051SAL
Process Connections 3051SAM: Flanges, NPT, Instrument Manifolds, 1199 Seals
3051SAL: Flanged, Threaded, and Hygienic direct-mount seals
Output 4-20 mA with HART (revision 6)
Measurement Span Up to 150 feet (45 meters)
Variables Differential Pressure
PHI
Related Product Tags:
air pressure sensor , VW Air Pressure Sensor , Peugeot Air Pressure Sensor , Manifold Air Pressure Sensor , Nissan Air Pressure Sensor , OPEL Air Pressure Sensor , Fiat Air Pressure Sensor , Engine Air Pressure Sensor , Daewoo Air Pressure Sensor , automotive air pressure sensor , Automobile Air Pressure Sensor , differential pressure sensor , force transducer , intake air pressure sensor , intake manifold , intake manifold absolute pressure sensor , intake manifold manifold , intake manifold pipe