CK200212 LCD air conditioning controller (LCD, cool)
CK200212 fully-automatic controller applies to internal climate control system for bus with LCD.
Main functions:fully-automatic, cool, fresh air, disinfection/self-check, memory, error alarm, interior temp. display, voltage auto-protection, shift function.
The shift function
1) Interior temp. display (press fresh air button for no less than 3S)
2) Hold cooling (press cooling button for no less than 3S)
Application
WINIA MANDO, HYUNDAI , YUTONG ,YUXIN Automotive Air Conditioner
Technical data
Power supply |
DC24V(DC20V-DC32V) |
Power consumption | 3W |
Current | Max.200mA |
Dimensions | 168X66X55mm |
Input |
1) Interior temp. sensor(25,Rb=5K,B=3274) 2) Defrost sensor(25,Rb=5K,B=3274) 3) Pressure sensor 4) A/C power(generator) 5) ACC power(battery) 6) Backlight power |
Output |
1) Condenser fan(max0.3A) 2) Fan high (max0.3A) 3) Fan medium (max0.3A) 4) Fan low (max0.3A) 5) Fresh air on (max0.3A) 6) Fresh air off (max0.3A) 7) Compressor clutch (max0.3A) 8) Excitation(max. 0.3A) |
Display | LCD |
Ambient temperature | -30805%95%RH Non-condensing |
Storage temperature | -10705%95%RH Non-condensing |
Display precision | Set temp for dual digit display, accuracy 1; Interior temp dual digit display, accuracy 1 |
Temperature test standard | Temp. control based on the temp. of return air inlet, the defrost sensor controls defrost temp., defrost on at 2, defrost off at 4 |
Connector | Plug DJ7171-3-21;terminal :DJ621-F3*0.6A tinned |
Faceplate level | IP43 |
EMC level | EN50081&EN50082-2 |
Security level | Applied to EN61010-II, Pollution degree: II |
Weight | 295g |