1. MODEL orderingIVS - HPU - A - S4005 S
1 2 3 4 5
Tabe-1: ManufactureIVS
Tabe-2: Product: HPU-Hydraulic Power Unit
Tabe-3: Operation code M-manual / A-auto
Tabe-4: Model Data S-single acting; D-double acting;
S/D4***-series, S/D5***-series, S/D7***-series See Chart-1
Tabe-5:S/P/C
S: Static pressure or burst
1. Static pressure: Conduct static pressure holding testing and record the leak volume (pressure differential)
2. Burst function: Conduct burst testing within the max. Output pressure and record the peak pressure
3. Or combine the static pressure testing and burst testing
P: Pulse, and it is only for the single acting pumps, frequency 0.5HZ,and the pulses deformation will be less than the pump volume when the pulse pressure within the static pressure
C: Auto calibration for pressure gauges.
Chart-1
4***series | |||||||||
Pump Ratio | Volume | Static pressure Kgf/cm2 | |||||||
Single acting | Double acting | Min. | Max. | ||||||
S- Volume per Stroke /ml |
Max. Volume ml/min |
D- Volume per Stroke /ml |
Max. Volume ml/min | ||||||
005 | 42 | 4200 | 84 | 8400 | 2.5 | 35 | |||
010 | 22 | 2200 | 44 | 4400 | 5 | 70 | |||
020 | 12 | 1200 | 24 | 2400 | 10 | 140 | |||
030 | 7.5 | 750 | 15 | 1500 | 15 | 210 | |||
040 | 6 | 600 | 12 | 1200 | 20 | 280 | |||
060 | 4 | 400 | 8 | 800 | 30 | 420 | |||
110 | 2 | 200 | 4 | 400 | 55 | 770 | |||
155 | 1.5 | 150 | 3 | 300 | 77.5 | 1085 | |||
240 | 1 | 100 | 2 | 200 | 120 | 1680 | |||
300 | 0.8 | 80 | 1.6 | 160 | 150 | 2100 | |||
5***series | |||||||||
Pump Ratio | Volume | Static pressure Kgf/ cm2 | |||||||
Pump Ratio | Single acting | Double acting | Min. | Max. | |||||
Volume per Stroke /ml |
Max. Volume ml/min |
Volume per Stroke /ml |
Max. Volume ml/min | ||||||
005 | 90 | 9000 | 180 | 18000 | 2.5 | 35 | |||
010 | 42 | 4200 | 84 | 8400 | 5 | 70 | |||
012 | 36 | 3600 | 72 | 7200 | 6 | 84 | |||
020 | 22.5 | 2250 | 45 | 4500 | 10 | 140 | |||
025 | 16 | 1600 | 32 | 3200 | 12.5 | 175 | |||
030 | 14 | 1400 | 28 | 2800 | 15 | 210 | |||
035 | 12 | 1200 | 24 | 2400 | 17.5 | 245 | |||
055 | 7.5 | 750 | 15 | 1500 | 27.5 | 385 | |||
070 | 6 | 600 | 12 | 1200 | 35 | 490 | |||
085 | 5 | 500 | 10 | 1000 | 42.5 | 595 | |||
105 | 4 | 400 | 8 | 800 | 52.5 | 735 | |||
140 | 3 | 300 | 6 | 600 | 70 | 980 | |||
195 | 2 | 200 | 4 | 400 | 97.5 | 1365 | |||
280 | 1.5 | 150 | 3 | 300 | 140 | 1960 | |||
440 | 1 | 100 | 2 | 200 | 220 |
Related Product Tags:
turbocharger balancing machine , balancing machine , battery tester , bench , body bench , body repair bench , repair bench , testing bench , auto bench , brake tester , Clutch Tester , common rail system , common rail test stand , common rail test bench , common rail tester , diesel fuel pump , diesel test bench , four wheel aligner