Scope
Biodiesel free and total glycerin has a thermal conductivity detector, hydrogen flame ionization, electron capture, flame photometric, five kinds of nitrogen and phosphorus detector can be equipped with a packed column or a capillary column. The instrument can be programmed temperature thermostat operation, or third-order operation. Instrument is highly integrated, advanced design, to achieve a higher degree of automation, it can detect parameters, temperature parameters set by the keyboard implementation. Can packed column and capillary pressure and stigma real-time display, the instrument uses a single air route structure, reasonable structure, stable and reliable performance, simple operation, easy maintenance.
Features
1, with power self-diagnosis function, stopwatch function (to facilitate flow measurement), running timer, power storage protection, keyboard lock and power supply with anti-interference function mutation.
2, automatic fault diagnosis: analysis end automatic exceeded prompted, provide diagnostic meet the national standard three ratios, TD shown, the component concentrations shown a variety of fault diagnostics and so on.
3, oven volume, intelligent opened the door and out of the system infinitely variable air volume, reducing the program up / cool down time after the system is stable equilibrium; furnace system :( temperature range) Ambient temperature + 6 ~ 400 .13-order program heating, heating rate of 0-50 / min; Increment 0.1 / min can recalibrate the oven temperature by the user, and arbitrarily set maximum temperature. Furnace temperature equilibrium time determined by the user.
4, all computerized key operations, large-screen LCD display, man-machine dialogue, easy to operate;
Technical parameter
1. Temperature control
Temperature control range: room temperature 7 -400(incremental 0.1 degrees C)
Rise order: three order
Rise rate: 0.1 -50 /min (incremental 0.1 )
2. Detector FID
Detection limit: less than 5 * 10-12g/s (sixteen -)
Baseline noise: less than 6 * 10-12A/H
The linear range is greater than or equal to 105
Stable time: less than 20min
3. Detector TCD
Sensitivity: 10000mV = ml/mg (sixteen -)
Baseline noise: less than 30uV (99.999 hydrogen carrier gas
4. FPD detector
Detection limit: 5 × 10-12g / s (N)
Baseline noise: 2 × 10-13A / H
Related Product Tags:
turbocharger balancing machine , balancing machine , battery tester , bench , body bench , body repair bench , repair bench , testing bench , auto bench , brake tester , Clutch Tester , common rail system , common rail test stand , common rail test bench , common rail tester , diesel fuel pump , diesel test bench , four wheel aligner