Global Auto Parts & Accessories Marketplace
Home » Product Directory » Material And Equipment » Test Instrument »

Sxbz Automatic Transformer Testing Cabinet

    • Application: Acura
    • Market Type:After Market 
    • FOB Price: Inquiry For It?
    • Other Price Term: C&F
    • Payment Terms: L/C, T/T
    • Samples: Not Available
    • Minimum Order: 1Set/Sets

Quick Details

  • Place of Origin:

    Wuhan, China

  • Samples:

    Not Available

  • Delivery Time:

    20 Working Days

  • Packing:

    Plywood Cases

  • Max. Production Capacity:

    100 Per Year

  • Export Ratio:

    31% - 40%

  • OE Experience:

    No

Product Name:Sxbz Automatic Transformer Testing Cabinet

Sxbz Automatic Transformer Testing Cabinet

Application

Acura

Product Description:

General information:
SXBZ series Transformer Test Bench is suitable for comprehensive ex-work and maintenance detecting for all kinds of transformers. It's widely used in the field of power supply and distribution, power transformer manufacturer, transformer maintenance center and etc.  

This series could be customized according the customer's requirements.
On Site Test




Features:

  Fully English interface.

 Two operation modes: by push button, or by computer. These two modes are protective interlocked, means after the user selected the mode, the system can be operated under this mode only.

 LCD screen, could display 18 parameters including three voltage, current and etc at same time. All the test data could be displayed on the screen at real time.

 Advanced processor and PLC controller adopted, high precision A/D convertor.  Data calculated, stored, printed and generated to test report automatically. The print format is customized.

 The test system could be customized to bench type, microcomputer type or any at user's option to be suitable for your test site.

 The voltage and current ratio is settable. PT, CT measuring range switching automatically, the test value is to be displayed directly.

 ACCESS database storage, all the parameters, test data, environmental temperature, test date and etc could be saved and generated to files, easy for browsing and analyzing.

 The power within low power factor range is measurable.

 Over load alarm, circuit miss connecting protection, miss operating protection, over voltage, over current protection and etc functions.

 More requires please kindly contact with us.

Main Test Items:

 Transformer No-load Loss Measurement. (Automatically adjust to rated voltage under non-rated.)

 Transformer No-load Current Measurement. (Automatically calculate no-load current percentage.)

 Transformer Load Loss Measurement.  (Automatically adjust to rated current & revised temperature.)

 Transformer Turn Ratios Measurement.

 Transformer DC Winding Resistance Measurement.

 Transformer Impedance Measurement. (Automatically adjusts to impedance voltage percentage under rated current & revised temperature)

 Transformer Power-Frequency Withstand Voltage (Hipot) Test.

 Transformer Inductive (frequency-doubling) Withstand Voltage (Hipot) Test.

 Transformer Temperature Rising Test

 Partial Discharge Test.

 Insulation Resistance, Absorption Ratio, Polarization Index Measurement.

 Transformer Impulse Voltage Test.

 Transformer Tap-Changer Test.

 Transformer Oil Test. (Chromatography, Oil Breakdown, Oil Dewpoint)

 External induction voltage regulator control(load & no-load test), input/output voltage, current monitoring and over-current protection.

 Voltage/Current transformer shift control.

 Single-phase voltage regulator control (power frequency test), input/output voltage, current monitoring and over-current protection.

Specifications:

Capacity of tested transformer:

50KVA~1000MVA

Voltage level:

6KV, 10KV, 35KV, 110KV, 220KV, 330KV, 500KV, 750KV, 1000KV

The accuracy of direct current testing:

0.2%

Testing current:

2A, 5A, 10A, 20A

Turn Ratio Testing accuracy:

0.2%

Testing area:

1~5000

No-load & load current, short circuit resist testing accuracy:

0.2%

No-load & load loss testing accuracy:

0.2%±0.05D

Power factor:

0.01-1.00

Output voltage of AC withstand voltage:

0-1000KV

Output Voltage of induced withstand voltage:

800V~20kV~80kV


More information, please kindly contact with us, we can customize the suitable test set according your requirements and give you the best quotation. Thank you!

Send your message to this supplier:

logo Ms. Ying Ying
Enter between 20 to 3,000 characters, English only.

Supplier Details

Sansion Power Electric Co. , Ltd.

Market Type: OE Market 
Business Type: Manufacturer
Main Product: Ac Dc Hipot Test Set, Ac Resonant Testing Equipment

You May Like:

Hv/LV Switch Cabinet Test Bench Application: Acura
Primary Current Injection Test Set Application: Acura
120kv/5mA High Voltage DC Hipot Test Set For DC Hi ... Application: Acura
Common Rail Injector Test Bench 12PSB-CRI Application: Universal
OEM No: 12PSB-C ...
ABS Application: audi
Test Application: Beiqi
Display For Mercedes GL X164, ML W164, R-Class W25 ... Application: MB ML W164, GL X ...
OEM No: AW-LCD- ...
Diesel Injection Nozzle Tester S80H Application: Isuzu, Hino, Nis ...
OEM No: S80H
High Quality Wheel Balancer
Didn't find what you are looking for?
Please send us Your Search Requirement, or you can Post a Buying Lead,
suppliers may contact you actively.

Send Message