Global Auto Parts & Accessories Marketplace
1.Introduction On load tap changer analyzer HYKC-2000 is mainly applied to test transient time, transition waveform, transition resistance, synchronization status of three phase. |
2.Test feature Test transformers of type Y0 Y and display resistance value directly Automatically analyze waveform fault and mark the fault. Automatically adjust resistance value and time range according to sampling data Transformer type is able to display to synchronization status of three phase; Be able to test with winding or without winding |
Four terminal connection mode and provide high accuracy of resistance measurement. Continuous test to save time of power off Make word report 800×480 colorized LCD with touch screen and high speed printer Store 1000 groups of data and also can be saved by USB flash disk |
3.Technical parameters Three phase constant current source charge,charge current: 3A/1A; 0.6A/0.2A Maximum voltage of the port: 24V Maximum range of transition resistance: 100 Measuring range: 1A0.420 0.2A10100 Record time of waveform:300ms |
Sample rate: 30k Resolution of time:0.1ms Resolution of resistance: 0.1 Accuracy of transition resistance: ±5% Reading±0.1 Accuracy of transient time: ±0.5% Reading±0.2mS Work Temperature: -10-40 Humidity: <85%RH |
Tags: On Load Tap Changer Ohmmeter Analyzer |
Related Product Tags:
turbocharger balancing machine , balancing machine , battery tester , bench , body bench , body repair bench , repair bench , testing bench , auto bench , brake tester , Clutch Tester , common rail system , common rail test stand , common rail test bench , common rail tester , diesel fuel pump , diesel test bench , four wheel aligner