OEM No/Model: WJ-hid50W
Life length: More than 3500 hours. Working temperature: - 40 centi degree to 105 centi degree HID- WJ50: Start- Up input voltage: 8- 17V Working input voltage: 9- 16V Cold start- Up current (DC12V) ≤ 9. 5A Warm start- Up current (DC12V) ≤ 5. 5A Norm current≤ 5. 2A Norm power: 50W+/ -1W Test: 1. Over voltage protection: When the voltage is below 7. 5V, Or above 18V, The ballast will stop working. 2. Open circuit, Short circuit and reverse voltage protection: When the output end is in open circuit and short circuit, The ballast will be protected in one and ten seconds respectively. While it is in reverse voltage, The ballast will stop working. 3. Constant power test. 4. Working temperature test. 5. Flashlight test. The lamp keeps working after the switch is on and off one time per second. 6. Flashover test. 7. Ignition and aging test. 8. Water and dust proof test. To soak the ballast with lamp on power in water for 12 hours. 9. Radiated interference and shock resistance test 10. Electromagnetic interference test.